安科瑞 繆凱倫
摘 要:夏(xia)季是多雨季節,如(ru)果降雨量比較大(da),而城(cheng)(cheng)市(shi)(shi)排水系統不能及(ji)時排水會造成(cheng)城(cheng)(cheng)市(shi)(shi)內(nei)澇。在(zai)這(zhe)種情況下,千(qian)萬(wan)千(qian)萬(wan)不要觸(chu)摸金(jin)(jin)屬燈桿(gan)、金(jin)(jin)屬廣告牌、電(dian)(dian)(dian)子(zi)站牌等室外用(yong)電(dian)(dian)(dian)設備,防止觸(chu)電(dian)(dian)(dian)事故的發生。除此(ci)之(zhi)外,觸(chu)電(dian)(dian)(dian)倒地會造成(cheng)二(er)次傷害——溺水。因此(ci),一旦城(cheng)(cheng)市(shi)(shi)發生內(nei)澇,要遠(yuan)離金(jin)(jin)屬燈桿(gan)、金(jin)(jin)屬廣告牌等用(yong)電(dian)(dian)(dian)設備。
??關鍵詞:路(lu)燈漏電(dian)(dian);路(lu)燈桿(gan)漏電(dian)(dian);金屬燈桿(gan);剩余電(dian)(dian)流(liu);人身觸電(dian)(dian);接地故障
??行業背景
??夏季是多雨季節(jie),如果降雨量比較大,而城市排(pai)(pai)水(shui)系統不(bu)能及時(shi)排(pai)(pai)水(shui)會造(zao)成(cheng)城市內澇。在(zai)這種情況下,千(qian)萬(wan)千(qian)萬(wan)不(bu)要觸摸金(jin)屬燈桿、金(jin)屬廣(guang)告牌、電子(zi)站牌等室外用電設備(bei),防止(zhi)觸電事故的發生。
??每年都會(hui)有類似事故發生而造成人員(yuan)傷亡的報導,教訓不(bu)為不(bu)深刻!
??為(wei)什么(me)會(hui)出現(xian)這(zhe)種現(xian)象(xiang)呢(ni)?我們看一(yi)下燈桿(gan)開關接線盒的位置便知(zhi),其多(duo)設置在燈桿(gan)的底(di)部,距離地(di)面(mian)只有(you)20cm~30cm,正常情況下沒有(you)問題(ti),即使淋雨問題(ti)也不大。但一(yi)旦(dan)浸水(shui)、水(shui)泡則(ze)很容易(yi)發(fa)生漏(lou)電事故。
??接線盒距離(li)地面(mian)只有20cm~30cm,如下圖,內澇時(shi)容易浸水。
??除(chu)此之(zhi)外,觸電(dian)倒地會造成二(er)次傷害——溺(ni)水。因此,一旦(dan)城市發(fa)生(sheng)內澇,要遠離(li)金屬燈桿、金屬廣告牌等用電(dian)設備(bei)。
??為了保障人(ren)民群眾生命安(an)全,全文強(qiang)制(zhi)性規(gui)范(fan)《建筑電氣及(ji)智能(neng)化通(tong)用規(gui)范(fan)》(報(bao)批稿)第4.6.5條明確規(gui)定:
??當采用剩余電流(liu)動作保護器(RCD)作為電擊防(fang)護附加防(fang)護措施時,應(ying)符合(he)下列規(gui)定:
??1、額定(ding)剩余電流動作值不應大于30mA;
??2、額定電(dian)流(liu)不超(chao)過32A的下列回路應裝設(she)剩余(yu)電(dian)流(liu)動作保護器(RCD):
??2.1供一般人員使用(yong)的電源插座回路;
??2.2 室內移動電氣設備;
??2.3人(ren)員可(ke)觸及的室外電氣設備。
??3 剩余電流(liu)動作保護器(RCD)不(bu)應作為僅(jin)有的保護措(cuo)施;
??4采(cai)用(yong)剩余(yu)電(dian)流動作保護器(qi)(RCD)時應(ying)裝設保護接(jie)地導(dao)體(PE)。
??該條第2款第3項條文說(shuo)明(ming)解釋道,室外(wai)電氣(qi)設(she)(she)(she)備(bei)(bei)包括室外(wai)移動設(she)(she)(she)備(bei)(bei)和燈(deng)箱廣告、電話亭、充電樁等室外(wai)固定設(she)(she)(she)備(bei)(bei),其電擊風險(xian)高(gao)于室內固定安(an)裝設(she)(she)(she)備(bei)(bei),因(yin)此(ci)從保護人身安(an)全出(chu)(chu)發作出(chu)(chu)此(ci)規(gui)定。
??2 產品介紹
??ASJ系(xi)(xi)列剩(sheng)余(yu)電(dian)(dian)(dian)(dian)流(liu)動作繼電(dian)(dian)(dian)(dian)器可與低壓(ya)(ya)斷路(lu)(lu)器或低壓(ya)(ya)接(jie)觸(chu)器等組(zu)成組(zu)合式剩(sheng)余(yu)電(dian)(dian)(dian)(dian)流(liu)保(bao)(bao)護裝置,主要(yao)適用于交(jiao)流(liu)50Hz,額(e)定電(dian)(dian)(dian)(dian)壓(ya)(ya)400V及以下的TT和(he)TN系(xi)(xi)統配電(dian)(dian)(dian)(dian)線(xian)路(lu)(lu),用來(lai)對電(dian)(dian)(dian)(dian)氣線(xian)路(lu)(lu)進行接(jie)地(di)故(gu)障(zhang)保(bao)(bao)護,防(fang)止接(jie)地(di)故(gu)障(zhang)電(dian)(dian)(dian)(dian)流(liu)引起的設備(bei)損壞和(he)電(dian)(dian)(dian)(dian)氣火災事故(gu),也可用來(lai)對人(ren)身觸(chu)電(dian)(dian)(dian)(dian)危險提供間接(jie)接(jie)觸(chu)保(bao)(bao)護。
??ASJ系(xi)列剩(sheng)余電流(liu)監(jian)測儀適(shi)合用于多回路的剩(sheng)余監(jian)測及報警分閘
??3 功能介紹
??ASJ系列剩(sheng)余(yu)電(dian)(dian)流動(dong)作繼電(dian)(dian)器具(ju)有(you)以(yi)下功能:A型(xing)或(huo)者(zhe)AC型(xing)剩(sheng)余(yu)電(dian)(dian)流測量,剩(sheng)余(yu)電(dian)(dian)流越(yue)限報警指示,額定剩(sheng)余(yu)動(dong)作電(dian)(dian)流可設定,極(ji)限不驅動(dong)時間可設定,兩(liang)組(zu)繼電(dian)(dian)器輸(shu)出,具(ju)有(you)就地,遠程“測試"、“復(fu)位"功能;
??ASJ系列剩余電(dian)流監(jian)測儀具有以下功能(neng):16路剩余電(dian)流監(jian)測,一路水浸報警(jing)輸(shu)出,2路DI輸(shu)入,自動重合(he)(he)閘功能(neng),報警(jing)16路報警(jing)輸(shu)出,遠程通訊(xun)功能(neng),遠程分合(he)(he)閘。
??4 技術指標
??ASJ系(xi)列剩余(yu)電流動作(zuo)繼電器技術指標
??ASJ系列剩余電流監測儀技術指標(biao)
??5 選用說明
??剩余電流動作繼電器在應用時(shi)應注意(yi)低壓系統的接線型式(shi)。
??其余(yu)接線型式需要(yao)改造成(cheng)以(yi)上兩(liang)種(zhong)型式使(shi)用,防止出(chu)線誤動作(zuo)或者不動作(zuo)的情況(kuang)。
??剩余電(dian)流互(hu)感器的選(xuan)擇應(ying)根據(ju)主回(hui)路的額定(ding)電(dian)流為參考(kao)選(xuan)擇,
??實際應如圖(tu)所示,互感器安裝在主回(hui)路或者支路上,通過測量剩(sheng)余(yu)電流判斷(duan)是否驅動(dong)(dong)斷(duan)路器動(dong)(dong)作。
??6 結語
??剩余電(dian)流(liu)監(jian)測(ce)(ce)產品對由獨立變壓器供電(dian)的(de)低壓配電(dian)系統線路和(he)(he)設備絕緣的(de)實(shi)時監(jian)控(kong),起到提前對漏(lou)電(dian)事故的(de)預(yu)警(jing)和(he)(he)漏(lou)電(dian)保(bao)護(hu)作用(yong)(yong),繼(ji)電(dian)器和(he)(he)監(jian)測(ce)(ce)儀可(ke)以提供持續實(shi)時監(jian)測(ce)(ce)和(he)(he)監(jian)控(kong),用(yong)(yong)高(gao)科技(ji)手(shou)段提高(gao)安全(quan)管(guan)理水平,遠(yuan)程監(jian)控(kong),漏(lou)電(dian)保(bao)護(hu)的(de)同時,提前預(yu)測(ce)(ce),預(yu)警(jing)和(he)(he)預(yu)排查,減(jian)少安全(quan)事故的(de)發生。
??為了防止事故發(fa)生,夏季雨天請遠離金屬燈桿等用電設(she)備,關愛生命(ming),不能抱有僥(jiao)幸(xing)心里(li)!